ProcessChem

Reactor

About

Size a reactor for the conversion you need, or find the conversion a reactor of a given size reaches, from the reaction's rate law. Plug flow, mixed flow (a stirred tank) or batch, isothermal.

What This Models

One reaction in one of the three ideal reactors. You give the balanced reaction (it balances itself, as in Reaction), the feed, the temperature and pressure, and the kinetics. The app works out how the conversion of the key reactant X rises through the reactor.

  • Plug flow: the feed moves through as a plug, with no mixing along the length. The conversion rises along it.
  • Mixed flow: a well-stirred tank. The whole contents are at the outlet's composition, so the reaction runs at the outlet's (lowest) rate.
  • Batch: a closed vessel filled once. The conversion rises with time.

Key Relations

With X the conversion of the key reactant A, F_A0 its molar feed rate, r the rate per volume (or per kg of catalyst) and V the volume (or the catalyst mass W):

  • Plug flow: dX/dV = r(X) / F_A0, so V = F_A0 ∫₀ˣ dX / r(X)
  • Mixed flow: V = F_A0 · X / r(X)
  • Batch, at constant volume: dX/dt = r(X) · V / N_A0

Every other amount follows from the balanced equation: n_i = n_i0 + ν_i · ξ, with the extent ξ = X · n_A0 / |ν_A|.

The rate is a power law: r = k · C_A^a · C_B^b, with an optional (1 − Q/K) factor. k is entered at the reactor temperature, or as k = A · exp(−Ea / RT). The orders a and b are yours: a for the key reactant, b for the second reactant in the equation.

Units of k. Concentrations are in mol/L, the way rate constants are usually published. So k is in (L/mol)^(n−1)/s for a total order n: 1/s for first order, L/(mol·s) for second. Per kg of catalyst, k is in L^n/(mol^(n−1)·kg·s).

Gas or liquid. A gas's concentrations come from the ideal-gas law at the reactor's temperature and pressure: C_i = y_i · P / RT. So when moles appear or disappear the volume changes with them, which is Levenspiel's ε, without having to enter it. A liquid keeps the feed's volumetric flow, or the batch's volume.

Reversible. Choose Reversible and the rate carries (1 − Q/K), where Q is the reaction quotient and K comes from the species' Gibbs energies at the reactor temperature. For a gas, Q is built from partial pressures in bar; an inert in the feed lowers them. For a liquid, Q is built from mole fractions among everything fed, the liquid taken as an ideal solution; a solvent counts only if you list it as a feed component. The conversion then stops at equilibrium. Even with One way, the equilibrium conversion of a gas-phase reaction is reported, with a warning if the answer passes it.

These are the textbook design equations for the ideal reactors (Levenspiel 1999; Fogler). See References.

Inputs

Card What you give
Reactor Plug flow, Mixed flow or Batch. Find: Size (give the target conversion) or Conversion (give the volume, the catalyst mass, or the batch time).
Feed Reaction in gas or liquid, then each feed component: tap it to give its name and how much. Given as offers, for a gas to a flow reactor, Molar flow, Mass flow, Volumetric flow (at the reactor's temperature and pressure) or Normal flow (at the Normal reference on the Units tab); for a gas batch, Moles, Mass or Volume; for a liquid, Concentration, or a molar or mass amount. A liquid also needs its total volumetric flow, and a batch its volume. A component may be named by name or by formula. A component that is not in the reaction is an inert: it does not react, but it dilutes the others and is listed in the feed and outlet table.
Conditions Temperature and pressure, held constant through the reactor.
Reaction Written with the feed above: the reactants are the feed components. Add the products; the equation balances itself. The key compound is a reactant: conversion is counted on it, and the card says which. An amber line appears if the reaction names a reactant that is not in the feed.
Rate k at this temperature, or Arrhenius A and Ea. The order in the key reactant and in the second reactant. One way or Reversible. Rate per volume or per kg of catalyst (flow reactors).

What comes back

  • Headline: the size for your conversion, or the conversion for your size. Under it is the comparison engineers draw on a Levenspiel plot: what a mixed-flow reactor would need for the same conversion as plug flow, or the other way round.
  • Reactor: space time τ = V/v₀ and space velocity 1/τ. For a catalyst, the weight time W/F_A0 instead. Also the Damköhler number (rate at the inlet × τ / C_A0) and, where it applies, the equilibrium conversion.
  • Chart: the conversion along the plug-flow reactor, or through the batch.
  • Feed and outlet: a table of every component, In beside Out, with its share (mol % or mass %) and its flow or amount, and a Total. The mass total is the same in and out, and a line under the table states it.
  • Outlet: each species' concentration.
  • Rate: at the inlet and at the outlet.
  • Heat: the heat the reaction releases (or absorbs) at this conversion. This is the heat to remove (or supply) to hold the temperature. Also ΔH of the reaction as written.

The opening example is ethane cracking to ethylene (Fogler): first order, k = 3.07 1/s at 1100 K, pure ethane at 6 atm. Its plug-flow volume matches the closed form with ε = 1, k·τ₀ = (1 + ε) ln 1/(1 − X) − ε·X. At 6 atm equilibrium stops this reaction near 47 %, so the example is Reversible, with a 40 % target.

When It Refuses

  • A target conversion at or past equilibrium (Reversible), or past complete conversion: only an infinitely large reactor gets there.
  • A key compound that is a product, or a key reactant that is not fed.
  • A liquid reaction without a volumetric flow, or a batch without its volume.
  • A rate per kg of catalyst for a batch: a batch here is per volume.

What This Does Not Do Yet

  • Not isothermal: the temperature is held. An adiabatic reactor, where the heat released raises the temperature along it, is not modelled. The heat output says how much has to be removed to hold it.
  • One reaction: competing reactions and selectivity are not modelled.
  • No pressure drop along a packed bed.
  • Non-ideal mixing: no dispersion or residence-time distribution between plug and mixed flow. Two ideal reactors are the bounds.
  • No rate data built in yet: the kinetics are yours to enter.

What was checked against published values, and how far off it was, is on Accuracy and limits.

References

Design equations and kinetics

  • Plug-flow, mixed-flow and batch design equations, space time and space velocity, the Levenspiel plot comparison, the volume change of a gas (ε), the power-law rate and the Arrhenius form: Levenspiel, O., Chemical Reaction Engineering, 3rd ed., Wiley, 1999.
  • The same design equations for catalyst mass (W/F_A0), the reversible rate with the (1 − Q/K) factor and the Damköhler number: Fogler, H. S., Elements of Chemical Reaction Engineering, Prentice Hall.
  • The default example (ethane cracking to ethylene, first order, k = 3.07 1/s at 1100 K, pure ethane at 6 atm, and the closed form k·τ₀ = (1 + ε) ln 1/(1 − X) − ε·X): Fogler, as above.

Thermodynamics

  • K from the species' Gibbs energies, the equilibrium conversion, the heat of reaction and the ideal-gas concentrations C = yP/RT: Smith, J. M., Van Ness, H. C., Abbott, M. M. and Swihart, M. T., Introduction to Chemical Engineering Thermodynamics, 8th ed., McGraw-Hill, 2018. The species data are those named on the Reaction page.

See also the combined list on Methods and sources.