Heater

About

Heats or cools a batch or a stream at constant pressure, or the contents of a sealed vessel. Give an outlet temperature and it finds the duty, or give a duty and it finds the temperature reached, with melting, boiling and sublimation included. With Vessel: Sealed, it also finds the pressure rise and the liquid level, and flags the liquid-full overpressure hazard.

Inputs
Inputs
Results
Results

What This Models

A heater or cooler at constant pressure: an exchanger, a steam coil, a trim cooler. The fluid is free to expand as it warms, so the energy that matters is its enthalpy.

A sealed rigid vessel is different: it cannot expand, so heating it raises its pressure and the energy that matters is internal energy instead. The Vessel switch at the top of the form chooses between the two. None · pressure held (the default) is for anything flowing through equipment or held at atmospheric pressure. Sealed · volume fixed is for a closed cylinder or drum, and is described under Vessel: Sealed. Switching carries the substance and the temperatures across.

The Vessel Heater used to be a case of its own. It is now this switch, with the same calculation, and sets saved as Vessel Heater open under Sealed.

Inputs

The form opens with a Set-up picture: the fluid entering at the inlet temperature, the heater, and the fluid leaving. It fills in as you type, with a ? on whatever the calculation will find: the heat when you give the outlet temperature, the outlet temperature when you give the duty. Below it the form is grouped Fluid, Amount, Inlet and Find. Every number has its own unit menu inside its field.

Fluid is a Single substance / Mixture switch. A single substance goes in Substance, which opens on Water. A mixture is built the same way as on the Property tab, with its shares given as Mole % or Mass %, or as Amounts: each component's own amount, in any of the units the Amount field offers. With amounts, the separate Amount field steps aside and the total is their sum. A component given as a volume is taken as that pure component at the inlet temperature and pressure. Air and the refrigerant blends have no heat-capacity data of their own, so on their own they are refused. As one component of a mixture they are accepted and split into their constituents (air into nitrogen, oxygen and argon).

Amount is one field, opening on a Mass flow of 1000 kg/h. As the note under it says, "Mass, moles or volume: pick any unit". The unit menu groups every unit under its kind: Mass flow, Molar flow, Volumetric flow and Normal Volumetric Flow for a stream, and Mass, Moles and Volume for a batch. Picking a unit of another kind switches the basis, and the field's label changes to match. Each kind keeps its own number, so nothing is converted across kinds. A rate heats a stream and reports a power; a quantity heats a batch and reports an energy. A volume or volumetric flow needs a density at the inlet conditions, and if none is available it says so and asks for a mass or moles instead.

Inlet has Temperature (20 °C) and Pressure (1.01325 bara) side by side. The pressure is held constant throughout; its ⓘ reminds you that a heater lets the fluid expand rather than building pressure as a sealed vessel does. It is also used to place the boiling point, so water heated at 20 bara is not refused for "boiling at 100 °C" when its real boiling point at that pressure is about 212 °C.

Find is a switch. The duty shows an Outlet temperature field, 120 °C by default, and finds the heat needed to get there. Outlet temperature shows a Duty field instead and finds the temperature reached. The duty is a power when the amount is a rate and an energy when it is a batch quantity. Enter a negative duty to cool. The duty direction is solved by root-finding the temperature whose enthalpy change matches the duty you gave.

Press Calculate, pinned at the bottom of the screen. Editing any input, or changing a unit, clears the answer, and you are back at the inputs.

What comes back

The results open on their own screen. At the top an Inputs strip sums up what was calculated ("Water · 1000 kg/h · 20 °C → 120 °C"), and Edit takes you back to the form.

The answer comes first, in a dark card: Heat duty for a stream, Heat required for a batch, or Heat removed when cooling, with a sentence saying what happened to the phase. For example, "Liquid in, gas out: 86 % of it goes into boiling", or "Stays liquid the whole way". Tap the unit beside the number to change it.

Under it the set-up picture comes back, now filled in with the inlet and outlet temperatures, each labelled with its phase, and the duty.

A Heating curve (or Cooling curve) card plots temperature against the heat added or removed. Flat steps on it are phase changes, and the card says so. When the range crosses a phase change, a bar under the chart splits the duty into its sensible and latent parts, with each part's share in per cent.

Then the values, grouped:

  • Duty: Heat duty (a stream) or Heat required (a batch). When the range crosses a phase change it is split into of which sensible and of which latent. Mean heat capacity (sensible) is shown for checking a duty by hand.
  • Conditions: Initial → final temperature and Initial → final phase on one row each, and a Melting point, Boiling point or Sublimation point line for each transition crossed.
  • Amount: the same amount every way, whichever basis you entered: mass, moles, and the volume at inlet conditions where a density exists. On a stream they are flows.

Above the values, a Stream by phase table gives the amount that is solid, liquid and gas, In beside Out, with a Total. Under it, a line states the mass balance: in = out. When a duty stops part-way through boiling, the Out column shows how much has boiled. A mixture gets Stream · every component instead. Share switches between mol % and mass %, and Amount sets the unit.

Every value with a unit has its own unit menu; changing one changes only that row.

A grey note says the duty is the change in enthalpy at constant pressure, and that a sealed rigid vessel behaves differently (set Vessel to Sealed for that). When the phase changes, a second note says the latent heat is included and shown separately. Amber warnings say when a number in the duty is an estimate: a heat of vaporisation from a corresponding-states correlation, a latent heat taken as the difference of two phase enthalpies because none is measured, a solid heat capacity from the Lastovka estimate, or a boiling point that could not be found at your pressure so the 1 atm value was used. Solved with: names the heat-capacity correlations used, and the tabulated latent heats where they applied. Methods used at the foot opens a sheet where you can see, and for a single substance change, the heat-capacity method used for each phase; picking another one calculates again. See Methods and Sources.

Duty Runs Out Mid-Transition

If you specify a duty and it runs out part-way through melting or boiling, the temperature simply stops at the transition, because enthalpy jumps there. The result says so in amber, adds a line such as Fraction vaporised at 100.0 °C giving how much of the material changed phase, and warns that both phases are present at the end. The heating curve ends part-way along its flat step, at the duty you entered. That matters when you sized for one phase.

A duty larger than the substance can absorb over the range its heat-capacity data covers, or one that runs past a phase change it has no latent heat for, is refused with a message suggesting a smaller duty or a specified outlet temperature.

Mixtures

A mixture is accepted as long as no component melts or boils inside the range asked for. Its duty is then the mole-weighted sum of each component's sensible heat, which is exact for an ideal mixture. A composition entered by mass is converted to moles first, because the duty is per mole of mixture. If any component does change phase in the range, the calculation is refused by name, for example "water boils at 100 °C, inside the range asked for", and suggests keeping the range on one side of it or heating that component on its own, since a mixture changes phase across a range rather than at one point.

Phase Changes Are Included

Unlike the Thermo tab, which refuses a range that crosses a melting or boiling point, this case walks the range in segments — integrating the solid, liquid or gas heat capacity as appropriate — and adds the latent heat at each boundary it crosses. A solid below its triple-point pressure never melts: it sublimes in one step where its sublimation pressure equals the pressure, for example CO₂ at −78.5 °C at 1 atm. Heating dry ice from −100 °C to 20 °C at 1 atm is one such range: the solid warms to −78.5 °C, sublimes there, and the gas warms to 20 °C. Each latent heat is chosen so that both ends sit on one reference; see One enthalpy reference.

Key Relations

Q = n·Δh                  duty is the enthalpy change, constant P
Δh = ∫Cp dT + Σ L_tr       sensible part plus each latent heat crossed

n is the amount (or flow); Cp is the heat capacity of whichever phase the range is in at that point; L_tr is the latent heat added at each melting or boiling point the range crosses. Given a duty instead of an outlet temperature, the same relation is root-found for the T whose Δh matches it. Heating water from -20 °C to 150 °C gives about 3.13 MJ/kg, of which roughly five sixths is L_tr — melting the ice and boiling the water — rather than the ∫Cp dT term. The duty is reported split into its sensible and latent parts for exactly that reason, and the transition temperatures are shown.

The enthalpy of vaporisation is read at the boiling point rather than at the starting temperature, which matters: water reads 2257 kJ/kg at 100 °C against 2442 kJ/kg at 25 °C.

Mean Heat Capacity

Cp_mean = (∫Cp dT)/(T₂ − T₁) — reported for checking a duty by hand, and it is the sensible heat divided by the temperature span only. Folding L_tr into it would give a number that looks like a heat capacity, is not one, and is wrong by however much of the duty went into the phase change.

Limitations

A mixture that stays in one phase across the range is fine (see Mixtures), but one whose components melt or boil in it is refused: a mixture boils across a range rather than at a point, so its latent heat cannot be placed at a single boundary. A solid that decomposes rather than melting is refused by name — calcium carbonate calcines to CaO and CO2 rather than turning into a liquid, and the enthalpy of fusion listed against it does not describe anything that happens. For a liquid, gas or supercritical fluid the duty is the enthalpy difference from the equation of state, so it holds at high pressure: nitrogen from 20 to 200 °C at 200 bar matches the reference within 0.1 %. A solid is still heated on its heat-capacity correlation, which is extrapolated outside its fitted range. Accuracy and limits has the measured deviations.

A handful of common plastics (HDPE, LDPE, polypropylene, PET, PVC) can be entered by name here too, heated over their solid range. None of them has a verified melt-phase model behind it, so a range reaching into or through the melt is refused rather than guessed — real resin properties also vary by grade, which the Property tab's entry for each one says more about.

Vessel: Sealed

Choose Sealed · volume fixed under Vessel. A sealed rigid vessel is heated or cooled, and the case finds the heat needed and the resulting pressure, phase and liquid level, and flags the liquid-full overpressure hazard.

Inputs
Inputs
Results
Results

What This Models

A rigid, sealed vessel whose contents are heated or cooled — fire exposure, solar gain, steam-out, loss of cooling, or an ambient swing. The vessel does not vent and does not change volume, so both the total volume and the mass inside are constant and the molar volume is fixed.

Inputs

With Sealed chosen, the form shows a Set-up picture of the vessel with its contents, the starting temperature ("now"), the target temperature, and the mass inside. It fills in as you type, with a ? for the final temperature when you give the heat instead. Below it the form is grouped Fluid, Vessel, Contents and Heating / cooling. Every number has its own unit menu inside its field.

Fluid is a Single substance / Mixture switch. A single substance goes in Substance, which opens on Propane. A mixture is built the same way as on the Property tab, with its shares given as Mole % or Mass %, or as Amounts: each component's own mass, in which case Mass in vessel steps aside and the mass is their sum.

Vessel is a Volume / Dimensions switch. Volume asks for one Vessel volume, 1000 L by default. Dimensions asks for:

  • Inside diameter (1 m) and Length (tangent to tangent) (2 m), side by side. The length is the straight shell only, excluding the heads, as its ⓘ says.
  • The head type, a switch of Elliptical (2:1), Hemispherical or Flat. Each head adds π·D³/24, π·D³/12 or nothing to the shell's π·D²·L/4.
  • The orientation, Vertical or Horizontal. It is recorded and does not change the volume or pressure here, but it sets how liquid level, wetted area and fill relate, which matters for relief and fire calculations. The results repeat this in amber.

A flat-headed vessel needs a non-zero length, or its volume would be zero.

Contents is a Mass / Pressure switch. Give a Mass in vessel (100 kg) and the app solves the initial state from it, or give an Initial pressure (10 bar) and the mass is back-calculated from the equation of state. Initial temperature is 20 °C, and sits beside the initial pressure when that is what you give.

Heating / cooling is a Final temperature / Heat added switch. Final temperature asks for the temperature to reach (80 °C) and finds the heat. Heat added asks for Heat added (negative to cool) and finds the temperature reached; as the note under it says, use a negative number to cool.

Press Calculate, pinned at the bottom of the screen. Editing any input, or changing a unit, clears the answer, and you are back at the inputs.

What comes back

The results open on their own screen. At the top an Inputs strip sums up what was calculated ("Propane · 100 kg · 20 °C → 80 °C"), and Edit takes you back to the form.

The answer comes first, in a dark card: Heat to add, with a sentence saying what the phase did, such as "Stays liquid+gas the whole way" or "Liquid+Gas at the start, liquid at the end". Tap the unit beside the number to change it. Under it is a picture of the vessel, labelled with its final phase, beside a thermometer running from the initial to the final temperature.

Three tiles follow: Final temp., Final phase, and Per kg, the heat divided by the mass in the vessel. Then the values, grouped:

  • Vessel: the Vessel volume, and for a vessel given by dimensions the Shell and the Heads (2) separately. Then the Contents (the mass inside) and its Moles.
  • Initial state and Final state, each with Temperature, Pressure, Phase and Vapour fraction ("single phase" if there is only one), and the Liquid volume, Vapour volume and Liquid fill as a percentage of the vessel. Liquid fill turns amber at 99.5 % or more.
  • Energy: Heat added (or Heat removed when cooling), and the Pressure rise between the two states.

A Contents by phase table gives the liquid and the vapour in the vessel at the Start and at the End, with a Total that stays the same, since the vessel is sealed; a line under it states that balance. A mixture also gets Contents · every component.

Every value with a unit has its own unit menu; changing one changes only that row.

Amber warnings appear under the values. LIQUID-FULL fires when heating removes the vapour space that was there at the start; see The Liquid-Full Warning. A final pressure above 1000 bara is flagged as far beyond ordinary equipment, with a reminder that the equation of state is being extrapolated. For a mixture, a warning says the liquid and vapour volume split uses bubble- and dew-point molar volumes that sit at different pressures (the temperature glide), so treat it as an approximation. An estimated or extrapolated density is called out too, because the mass in the vessel comes straight from it. The Phase Equilibrium caveats appear here as well: below the melting point, liquid density from Peng-Robinson, and a missing interaction parameter.

Solved with: names the equation of state that produced the states. Methods used at the foot opens a sheet showing it; for a single substance that has a reference equation, you can switch between Reference equation (CoolProp) and Peng-Robinson cubic, and the case calculates again. See Methods and Sources.

Method

Constant volume and constant mass fix the molar volume; the final state then follows from the first law with no work term, in either direction.

Key Relations

V_m = V/n                    fixed, from the constant volume and mass
Q = n·(U₂ − U₁)               final temperature given -> duty found
U₂ = U₁ + Q/n                 duty given -> target U, then T solved

V_m is the molar volume, fixed for the whole calculation. Given a final temperature, the final state is a T,V_m flash and the duty follows directly. Given a duty instead, the target internal energy U₂ is known and the final temperature is found by root-finding on that same T,V_m flash.

The two-phase region is handled explicitly rather than left to the equation of state: a plain T,V_m flash inside the saturation dome puts the liquid under tension and returns a negative pressure, so the saturation envelope is checked first and a two-phase state is solved at the vapour fraction x satisfying x·V_m,g + (1−x)·V_m,l = V_m — the fraction that reproduces the vessel's own molar volume.

The Liquid-Full Warning

When heating drives the vapour fraction to zero, the vessel is liquid-full. Past that point there is no compressible vapour space left, and pressure rises almost vertically with temperature — a few degrees more can mean hundreds of bara. The calculation still reports a number, but it is extremely sensitive to both the temperature and the accuracy of the liquid density, so treat it as an indication that relief is required, not as a design pressure.

Limitations

The vessel is rigid (no elastic expansion of the shell, which in reality relieves a little of the hydraulic pressure rise), perfectly sealed, and uniform in temperature. Vessel wall heat capacity is not included, so a given duty heats the contents faster than it would in reality. There is no relief device — this is the unrelieved case, which is exactly what you size relief against. For a liquid-full mixture the pressure rise comes from Peng-Robinson and was about 20 % low against the reference for propane/butane; see Accuracy and limits.

References

  • Duty as an enthalpy change, Q = n·Δh = n(∫Cp dT + Σ L_tr), and mean heat capacity: Smith, J. M.; Van Ness, H. C.; Abbott, M. M.; Swihart, M. T. Introduction to Chemical Engineering Thermodynamics, 8th ed.; McGraw-Hill: New York, 2018. Also Çengel, Y. A.; Boles, M. A. Thermodynamics: An Engineering Approach, McGraw-Hill.
  • Sealed vessel (Q = n·(U₂ − U₁), T,V_m flash, two-phase state from the vapour fraction x): the same textbook thermodynamics, Smith, Van Ness, Abbott and Swihart as above. The equation of state and flash are the ones named below.
  • Latent heat read at the transition temperature, and carrying it to another temperature along the heat-capacity curves (Kirchhoff); heat of sublimation from the slope of the sublimation-pressure curve (Clausius-Clapeyron): Smith, Van Ness, Abbott and Swihart, as above. The ordering of data sources is described under One enthalpy reference.
  • Reference equations of state (CoolProp): Bell, I. H.; Wronski, J.; Quoilin, S.; Lemort, V. Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp. Ind. Eng. Chem. Res. 2014, 53, 2498-2508.
  • Peng-Robinson cubic equation of state: Peng, D.-Y.; Robinson, D. B. A New Two-Constant Equation of State. Ind. Eng. Chem. Fundam. 1976, 15, 59-64.
  • Fitted interaction parameters for mixtures: the ChemSep database (Kooijman, H. A.; Taylor, R.), www.chemsep.org.
  • Heat capacity, heat of fusion, enthalpy of vaporisation and melting point correlations, and the saturation (flash) calculations: property correlations fitted to measured data. Poling, B. E.; Prausnitz, J. M.; O'Connell, J. P. The Properties of Gases and Liquids, 5th ed.; McGraw-Hill: New York, 2001, is the general reference for the correlations of this kind.
  • Heat capacity of ice (water below 0 °C): Feistel, R.; Wagner, W. A New Equation of State for H2O Ice Ih. J. Phys. Chem. Ref. Data 2006, 35, 1021-1047 (IAPWS-06).
  • Heat capacity of solid carbon dioxide (dry ice): Giauque, W. F.; Egan, C. J. J. Chem. Phys. 1937, 5, 45.
  • Solid heat capacity estimate (Lastovka method), where no measured data exist: Laštovka, V.; Fulem, M.; Becerra, M.; Shaw, J. M. A Similarity Variable for Estimating the Heat Capacity of Solid Organic Compounds: Part II. Application: Heat Capacity Calculation for Ill-Defined Organic Solids. Fluid Phase Equilib. 2008, 268, 134-141.
  • Water-based salt solutions (Laliberté): Laliberté, M. A Model for Calculating the Heat Capacity of Aqueous Solutions, with Updated Density and Viscosity Data. J. Chem. Eng. Data 2009, 54, 1725-1760.
  • Heats of sublimation (NIST WebBook): Linstrom, P. J.; Mallard, W. G., Eds. NIST Chemistry WebBook, NIST Standard Reference Database Number 69, https://doi.org/10.18434/T4D303.
  • The vessel's head volumes (π·D³/24, π·D³/12) and shell volume (π·D²·L/4) are plain geometry and need no source.